- Totalt 0,00 kr
RS-25-24 Switchat Nätaggregat - 25 W - 24 V
25 W - 24 V Switchat Nätaggregat
Lägg till en bevakning så meddelar vi dig så snart varan är i lager igen.
RS-25-24 Switchat Nätaggregat - 25 W - 24 V
25 W - 24 V Switchat Nätaggregat
- Universal AC ingång
- LED indikator för on/off
- Hög driftstemperatur med upp till 70 °C
- Hög effektivitet, lång livstid och hög tillförlitlighet
- Skydd mot: kortslutning / överladdning / överspänning
Specifications
- output:
- DC voltage: 24 V
- rated current: 1.1 A
- current range: 0-1.1 A
- rated power: 26.4 W
- ripple & noise (max.): 120 mVp-p
- voltage adj. range: 22-27.6 V
- voltage tolerance: ± 1.0 %
- line regulation: ± 0.5 %
- load regulation: ± 0.5 %
- setup, rise time:
- 1800 ms, 23 ms / 230 VAC
- 4000 ms, 30 ms / 115 VAC at full load
- hold up time (typ.):
- 80 ms / 230 VAC
- 14 ms / 115 VAC at full load
- input:
- voltage range:
- 88-264 VAC
- 125-373 VDC
- withstands 300 VAC surge for 5 s
- frequency range: 47-63 Hz
- efficiency (typ.): 86 %
- AC current (typ.):
- 0.7 A / 115 VAC
- 0.4 A / 230 VAC
- inrush current (typ.): cold start 30 A / 230 VAC
- leakage current: < 2 mA / 240 VAC
- voltage range:
- protection:
- overload:
- 110-180 % rated output power
- protection type: hiccup mode, recovers automatically after fault condition is removed
- overvoltage:
- 27.6-32.4 V
- protection type: shuts off output voltage, clamping by zener diode
- overload:
- environment:
- operating temperature: -25 to +70 °C
- operating humidity: 20-90 % RH non-condensing
- storage: -40 to +85 °C, 10-95 % RH
- temperature coefficient: ± 0.03 %/°C (0-50 °C)
- vibration: 10-500 Hz, 5G 10 min/1 cycle, period for 60 min each along X, Y, Z axes
- safety & EMC:
- safety standards: UL60950-1, TÜV EN60950-1 approved
- withstand voltage:
- input to output: 3 kVAC
- input to ground: 1.5 kVAC
- output to ground: 0.5 kVAC
- isolation resistance: input to output, input to ground, output to ground: 100 Mohm / 500 VDC / 25 °C / 70 % RH
- EMC emission: compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3
- EMC immunity: compliance to EN61000-4-2,3,4,5,6,8,11; EN61000-6-2 (EN50082-2), heavy industry level, criteria A
- other:
- MTBF: min. 309,700 h, MIL-HDBK-217F (25 °C)
- dimensions: 78 x 51 x 28 mm
- weight: 0.2 kg